{"id":459,"date":"2026-05-22T15:43:39","date_gmt":"2026-05-22T14:43:39","guid":{"rendered":"https:\/\/tout-en-un.com\/?p=459"},"modified":"2026-05-24T10:53:52","modified_gmt":"2026-05-24T09:53:52","slug":"types-onduleurs","status":"publish","type":"post","link":"https:\/\/tout-en-un.com\/index.php\/2026\/05\/22\/types-onduleurs\/","title":{"rendered":"Les types D&rsquo;onduleurs"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Les onduleurs se classent par <strong>forme physique<\/strong>, <strong>architecture des batteries<\/strong>, <strong>technologie de conversion<\/strong> et <strong>puissance (kVA)<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Voici les types principaux :<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"795\" height=\"528\" src=\"https:\/\/i0.wp.com\/tout-en-un.com\/wp-content\/uploads\/2026\/05\/types_onduleur.png?resize=795%2C528&#038;ssl=1\" alt=\"onduleurs\" class=\"wp-image-466\" srcset=\"https:\/\/i0.wp.com\/tout-en-un.com\/wp-content\/uploads\/2026\/05\/types_onduleur.png?w=795&amp;ssl=1 795w, https:\/\/i0.wp.com\/tout-en-un.com\/wp-content\/uploads\/2026\/05\/types_onduleur.png?resize=300%2C199&amp;ssl=1 300w, https:\/\/i0.wp.com\/tout-en-un.com\/wp-content\/uploads\/2026\/05\/types_onduleur.png?resize=768%2C510&amp;ssl=1 768w, https:\/\/i0.wp.com\/tout-en-un.com\/wp-content\/uploads\/2026\/05\/types_onduleur.png?resize=600%2C398&amp;ssl=1 600w\" sizes=\"auto, (max-width: 795px) 100vw, 795px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">1. Par forme physique (int\u00e9gration dans l\u2019environnement IT)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Onduleur de type Tour (Tower)<\/strong><br>Con\u00e7u pour rester debout au sol. Souvent utilis\u00e9 pour un unique serveur tour, un NAS ou un poste de travail haut de gamme.<\/li>\n\n\n\n<li><strong>Onduleur de type Rack (montage en baie)<\/strong><br>Format 19 pouces, hauteur en U (1U, 2U, 3U). Se fixe dans une armoire r\u00e9seau\/serveur. Permet une int\u00e9gration propre avec d\u2019autres \u00e9quipements IT.<\/li>\n\n\n\n<li><strong>Onduleur mixte Tour\/Rack<\/strong><br>Livr\u00e9 avec pieds (tour) et oreilles (rack). Peut changer de mode selon le besoin.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">2. Par gestion des batteries<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Avec batterie int\u00e9gr\u00e9e (interne)<\/strong><br>Type le plus courant pour petites et moyennes puissances (300 VA \u00e0 3000 VA). Batteries scell\u00e9es au plomb (AGM) ou lithium.<br><em>Inconv\u00e9nient :<\/em> autonomie limit\u00e9e (5-30 min en g\u00e9n\u00e9ral). Changement de batterie possible mais d\u00e9montage requis.<\/li>\n\n\n\n<li><strong>Avec batteries externes (EBM \u2013 Extended Battery Module)<\/strong><br>L\u2019onduleur contient des batteries internes limit\u00e9es, mais il dispose d\u2019une connectique pour ajouter un ou plusieurs modules externes (EBM) du m\u00eame fabricant.<br>Utilis\u00e9 pour augmenter l\u2019autonomie (ex : garder des serveurs critiques allum\u00e9s 1-4 heures).<\/li>\n\n\n\n<li><strong>Onduleur sans batterie (pr\u00eat pour batterie externe)<\/strong><br>Rare dans le petit informatique. Plut\u00f4t pour les gros onduleurs modulaires (10 kVA et plus), o\u00f9 l\u2019utilitaire choisit le parc batteries externe.<\/li>\n\n\n\n<li><strong>Onduleur \u00ab batterie rempla\u00e7able \u00e0 chaud \u00bb (hot-swap)<\/strong><br>Permet de changer une batterie d\u00e9faillante sans couper l\u2019alimentation des \u00e9quipements informatiques.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">3. Par technologie de conversion (impact la protection)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">C\u2019est le plus important pour la qualit\u00e9 de l\u2019alimentation des serveurs.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Onduleur \u00ab\u00a0Offline\u00a0\u00bb ou \u00ab\u00a0Standby\u00a0\u00bb<\/strong><\/li>\n\n\n\n<li>Mode normal : le secteur alimente directement l\u2019ordinateur.<\/li>\n\n\n\n<li>En panne : bascule sur batterie en 2-10 ms.<\/li>\n\n\n\n<li>Usage : bureautique, petit switch, PC non critique.<\/li>\n\n\n\n<li><em>Peu co\u00fbteux, mais filtrage moyen.<\/em><\/li>\n\n\n\n<li><strong>Onduleur \u00ab\u00a0Line-Interactive\u00a0\u00bb<\/strong> (le plus r\u00e9pandu pour IT)<\/li>\n\n\n\n<li>R\u00e9gulation automatique de la tension (AVR) sans passer par la batterie.<\/li>\n\n\n\n<li>Absorbe les micro-coupures et surtensions l\u00e9g\u00e8res.<\/li>\n\n\n\n<li>Usage : serveurs, NAS, \u00e9quipements r\u00e9seau, postes pro.<\/li>\n\n\n\n<li>Meilleur rapport qualit\u00e9-prix.<\/li>\n\n\n\n<li><strong>Onduleur \u00ab\u00a0Online\u00a0\u00bb (Double conversion)<\/strong><\/li>\n\n\n\n<li>Transforme toujours secteur \u2192 DC \u2192 AC. Z\u00e9ro temps de bascule.<\/li>\n\n\n\n<li>Sortie parfaite : onde sinuso\u00efdale pure, ind\u00e9pendante du secteur entrant.<\/li>\n\n\n\n<li>Usage : datacenters, serveurs critiques, mat\u00e9riel m\u00e9dical, \u00e9quipements sensibles.<\/li>\n\n\n\n<li>Plus cher, ventil\u00e9, parfois moins efficace (mais les modernes en mode \u00e9co).<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Attention :<\/strong> pour une alimentation informatique r\u00e9cente (alimentation PFC active), il faut <strong>obligatoirement un onduleur \u00e0 onde sinuso\u00efdale pure<\/strong> (line-interactive ou online). Les onduleurs \u00e0 \u00ab\u00a0onde approximative\u00a0\u00bb (modifi\u00e9e) peuvent faire planter ou griller les alimentations.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">4. Par puissance en VA \/ Watt<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Petit : 400 \u00e0 800 VA<\/strong> (240-500 W) : box internet, petit switch, t\u00e9l\u00e9phone IP.<\/li>\n\n\n\n<li><strong>Moyen : 1000 \u00e0 2200 VA<\/strong> (600-2000 W) : PC + \u00e9cran + NAS + routeur ; un serveur rack.<\/li>\n\n\n\n<li><strong>Grand : 3000 VA<\/strong> (2700 W) : serveur puissant, baie r\u00e9seau compl\u00e8te.<\/li>\n\n\n\n<li><strong>Modulaire : 5 \u00e0 20 kVA<\/strong> (en rack 10-19U) : petite salle serveur, datacenter \u2013 on ajoute des blocs de puissance et batteries au besoin.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">5. Autres crit\u00e8res sp\u00e9cifiques \u00e0 l\u2019informatique<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Onduleur avec communication r\u00e9seau (SNMP)<\/strong> : pour supervision via Nagios, PRTG, etc.<\/li>\n\n\n\n<li><strong>Onduleur avec USB + HID (Powershute)<\/strong> : arr\u00eat automatique du NAS (Synology, QNAP) ou serveur Windows\/Linux.<\/li>\n\n\n\n<li><strong>Prise PDU commut\u00e9e (switched PDU)<\/strong> : permet de red\u00e9marrer \u00e0 distance une prise sans \u00e9teindre les autres \u00e9quipements.<\/li>\n\n\n\n<li><strong>Hot-swap modules de puissance<\/strong> : pour les gros racks, remplacement d\u2019un module \u00e9lectronique sans coupure.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Exemples concrets d\u2019usage<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Besoin<\/th><th>Type recommand\u00e9<\/th><\/tr><\/thead><tbody><tr><td>Prot\u00e9ger 1 PC + 1 \u00e9cran<\/td><td>Tour line-interactive, 1000-1500 VA, batterie interne<\/td><\/tr><tr><td>42U de serveurs en datacenter<\/td><td>Rack online double conversion, 10 kVA, batteries externes EBM<\/td><\/tr><tr><td>1 serveur NAS (<a href=\"https:\/\/tout-en-un.com\/index.php\/product\/serveur-synology\/\">DS923+<\/a>) + switch + box<\/td><td>Rack 1U line-interactive, 700-1000 VA, onde sinuso\u00efdale pure<\/td><\/tr><tr><td>Sauvegarde longue dur\u00e9e (1h+) pour un serveur critique<\/td><td>M\u00eame onduleur mais ajout de 2-3 modules EBM<\/td><\/tr><tr><td>T\u00e9l\u00e9travail avec micro-coupures (courant instable rural)<\/td><td>Line-interactive avec AVR (\u00e9vite de solliciter la batterie)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">R\u00e9sum\u00e9 rapide pour choix informatique<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Tower<\/strong> : pour bureau ou petit serveur non int\u00e9gr\u00e9 en armoire.<\/li>\n\n\n\n<li><strong>Rack<\/strong> : pour baie standardis\u00e9e.<\/li>\n\n\n\n<li><strong>Batterie interne<\/strong> : autonomie courte (5-20 min) \u2013 suffisant pour arr\u00eat automatique.<\/li>\n\n\n\n<li><strong>Batterie externe (EBM)<\/strong> : autonomie longue (>30 min) ou maintien de charge apr\u00e8s plusieurs coupures courtes.<\/li>\n\n\n\n<li><strong>Line-Interactive<\/strong> : meilleur compromis pour 90 % des usages IT.<\/li>\n\n\n\n<li><strong>Online<\/strong> : uniquement si coupure zero ou \u00e9quipement ultra-sensible.<\/li>\n\n\n\n<li><strong>Puissance<\/strong> : un serveur = souvent 1-3 kVA. Une baie = 5-20 kVA.<\/li>\n\n\n\n<li><strong>Onde sinuso\u00efdale pure<\/strong> : imp\u00e9ratif pour alimentations PC\/serveur modernes.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Les onduleurs se classent par forme physique, architecture des batteries, technologie de conversion et puissance (kVA). Voici les types principaux [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-459","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/tout-en-un.com\/index.php\/wp-json\/wp\/v2\/posts\/459","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tout-en-un.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tout-en-un.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tout-en-un.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tout-en-un.com\/index.php\/wp-json\/wp\/v2\/comments?post=459"}],"version-history":[{"count":4,"href":"https:\/\/tout-en-un.com\/index.php\/wp-json\/wp\/v2\/posts\/459\/revisions"}],"predecessor-version":[{"id":469,"href":"https:\/\/tout-en-un.com\/index.php\/wp-json\/wp\/v2\/posts\/459\/revisions\/469"}],"wp:attachment":[{"href":"https:\/\/tout-en-un.com\/index.php\/wp-json\/wp\/v2\/media?parent=459"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tout-en-un.com\/index.php\/wp-json\/wp\/v2\/categories?post=459"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tout-en-un.com\/index.php\/wp-json\/wp\/v2\/tags?post=459"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}